C6 Multifunction Safety Controller
|
 |
| The C6 Multifunction Safety Controller acts as an interface between various Tapeswitch sensing devices and a machine or process control. It is designed to monitor up to six zones consisting of 1 to 3 B-Series Light Curtains and/or 1 to 6 other sensing devices. The C6 safety controller provides power to all connected B-Series Light Curtain emitters and receivers and monitors the output signals. In addition to the light curtains, the C6 safety controller interfaces with various pressure-sensitive, normally-open switches made by Tapeswitch including ribbon switches, sensing edges/bumpers, and switching mats. |
 |
 |
|
|
Features & Benefits |
- Controls up to 6 safety zones from one location
- Detects sensor, cabling or internal faults
- Automatic or manual reset or combination
- Visual status display of all zones
- Compatible with Tapeswitch sensing products
|
| The C6 safety controller incorporates built-in fault protection. It automatically detects an open or short within the sensor or its connecting cable and can also detect internal failures. |
| The C6 safety controller is a fully self-contained unit housed in a rugged metal enclosure. It is designed to be wall mounted and has six knockouts that accept standard 1/2" or 3/4" conduit. It will accept an input power source range of 85 to 264 Vac at an input frequency range of 47 to 63 Hz. The unit will also accept a regulated 24 Vdc supply. |
 |
| Technical Specifications for C6 Safety Controller |
|
| Supply Voltage |
110/240 Vac 50/60 Hz or 24 Vdc |
| Power Consumption |
30 VA typical |
| Enclosure Type |
Metal wall mount |
| Protection Rating |
NEMA 1/IP10 (Standard), NEMA 12/IP52 (Optional) |
| Weight |
9.5 lb (4.3 kg) |
| Reset Mode |
Automatic, manual, or combination |
| Output Relays |
Force guided safety relays
6.0 A @ 240 Vac, resistive load |
| Monitor Output |
Non-safety 6X (N/O or N/C)
10 A @ 240 Vac, resistive load |
| Operating Temperature |
32 to 122 ºF (0 to 50 ºC) |
| Response Time |
10 ms |
|