| Follow the procedure below, selecting the proper component at each step. For technical assistance, contact us at 1-800-234-8273 or by email. |
| 1. Select a Sensing Unit - Sensing units come in pairs; one emitter and one receiver. |
- Determine the resolution needed (14mm, 30mm, or 70mm).
- Determine the coverage length needed (200mm to 1800mm).
- Select the appropriate Sensing Unit from the table.
|
| B-Series Safety Light Curtain Models |
| 14mm Resolution |
30mm Resolution |
70mm Resolution |
| Length |
P/N |
Length |
P/N |
Length |
P/N |
Length |
P/N |
| 200mm (8in.) |
0912 |
200mm (8in.) |
0901 |
1400mm (56in.) |
0909 |
600mm (24in.) |
0921 |
| 300mm (12in.) |
0913 |
300mm (12in.) |
0902 |
1600mm (64in.) |
0910 |
800mm (32in.) |
0922 |
| 400mm (16in.) |
0914 |
400mm (16in.) |
0903 |
1800mm (72in.) |
0911 |
1000mm (40in.) |
0923 |
| 600mm (24in.) |
0915 |
600mm (24in.) |
0904 |
|
|
1200mm (48in.) |
0924
|
| 800mm (32in.) |
0916 |
800mm (32in.) |
0905 |
|
|
1400mm (56in.) |
0925 |
| 900mm (36in.) |
0917 |
900mm (36in.) |
0906 |
|
|
1600mm (64in.) |
0926 |
| 1000mm (40in.) |
0918 |
1000mm (40in.) |
0907 |
|
|
1800mm (72in.) |
0927 |
| 1200mm (48in.) |
0919 |
1200mm (48in.) |
0908 |
|
|
|
|
| 2. Select Cable Assemblies - One each for emitter and receiver. Cable length can be adjusted in the field. |
- Determine minimum cable length required for emitter unit.
- Determine minimum cable length required for receiver unit.
- Select the one emitter cable and one receiver cable from the table.
|
| Cable Assemblies |
Part Number |
| Emitter Cable, 15ft. |
5 Conductor |
0972 |
| Emitter Cable, 30ft. |
5 Conductor |
0973 |
| Emitter Cable, 98ft. |
5 Conductor |
0976 |
| Receiver Cable, 15ft. |
8 Conductor |
0974 |
| Receiver Cable, 30ft. |
8 Conductor |
0975 |
| Receiver Cable, 98ft. |
8 Conductor |
0977 |
| 3. Select Mounting Brackets - These are optional. Sensing Units come with standard mounting brackets. |
- Determine if standard mounting brackets will suffice. Consult your Tapeswitch application specialist.
- If required, select optional swivel, clamping, or vibration-damping mounting brackets.
|
| 4. Select Floor Stands - These are optional. |
- Determine if floor stands are required. Consult your Tapeswitch application specialist.
- If required, select the number of floor stands required.
|
| 5. Select Mirror Assemblies - These are optional. |
- Determine if mirrors are required. Consult your Tapeswitch application specialist.
- If required, select the appropriate mirror type from the table.
|
| Mirror Assemblies |
| Curtain Length |
Mirror Assembly Length |
Part Number |
| 200mm (8in.) |
300mm (12in.) |
0960 |
| 300mm (12in.) |
400mm (16in.) |
0961 |
| 400mm (16in.) |
500mm (20in.) |
0962 |
| 600mm (24in.) |
700mm (28in.) |
0963 |
| 800mm (32in.) |
900mm (36in.) |
0964 |
| 900mm (36in.) |
1000mm (40in.) |
0965 |
| 1000mm (40in.) |
1100mm (44in.) |
0966 |
| 1200mm (48in.) |
1300mm (52in.) |
0967 |
| 1400mm (56in.) |
1500mm (60in.) |
0968 |
| 6. Select Safety Controller - This is optional, but recommended. |
- Determine if a safety controller is required.
- If required, select a safety controller: BSRSA, BSRUA-2, SRUB, SRUS, C6, or BC-1.
|
| 7. Select Power Supply - This is optional. |
- If an SRUB Safety Controller has been selected, determine if you need a power supply.
- If required, select the GDC1 Power Supply.
|
| 8. Select Additional Accessories - These optional accessories provide useful functions for installing, maintaining and troubleshooting the light curtains. |
| Programming Unit - Used to program fixed and floating blanking on the sensing units.
Laser Alignment Tool - Provides a visual indication of alignment between the emitting and receiving unit. Simplifies alignment, especially when then units are far apart.
Diagnostic Software Kit - Interfaces the safety light curtain sensing units to a laptop computer. Shows real-time status of each beam and logs data. |
| |
|
 |