How-To-Order B-Series Safety Light Curtains
Follow the procedure below, selecting the proper component at each step. For technical assistance, contact us at 1-800-234-8273 or by email.
1. Select a Sensing Unit - Sensing units come in pairs; one emitter and one receiver.
  • Determine the resolution needed (14 mm, 30 mm, or 70 mm).
  • Determine the coverage length needed (200mm to 1800 mm).
  • Select the appropriate Sensing Unit from the table.
B-Series Safety Light Curtain Models
14 mm Resolution
30 mm Resolution
70 mm Resolution
Length
P/N
Length
P/N
Length
P/N
Length
P/N
200 mm (8")
0912
200 mm (8")
0901
1400 mm (56")
0909
600 mm (24")
0921
300 mm (12")
0913
300 mm (12")
0902
1600 mm (64")
0910
800 mm (32")
0922
400mm (16")
0914
400 mm (16")
0903
1800 mm (72")
0911
1000 mm (40")
0923
600 mm (24")
0915
600 mm (24")
0904
 
 
1200 mm (48")
0924
800 mm (32")
0916
800 mm (32")
0905
 
 
1400 mm (56")
0925
900 mm (36")
0917
900 mm (36")
0906
 
 
1600 mm (64")
0926
1000 mm (40")
0918
1000 mm (40")
0907
 
 
1800 mm (72")
0927
1200 mm (48")
0919
1200 mm (48")
0908
 
 
 
 
2. Select Cable Assemblies - One each for emitter and receiver. Cable length can be adjusted in the field.
  • Determine minimum cable length required for emitter unit.
  • Determine minimum cable length required for receiver unit.
  • Select the one emitter cable and one receiver cable from the table.
Cable Assemblies Part Number
Emitter Cable, 15 ft.
5 Conductor
0972
Emitter Cable, 30 ft.
5 Conductor
0973
Emitter Cable, 98 ft.
5 Conductor
0976
Receiver Cable, 15 ft.
8 Conductor
0974
Receiver Cable, 30 ft.
8 Conductor
0975
Receiver Cable, 98 ft.
8 Conductor
0977
3. Select Mounting Brackets - These are optional. Sensing Units come with standard mounting brackets.
  • Determine if standard mounting brackets will suffice. Consult your Tapeswitch application specialist.
  • If required, select optional swivel, clamping, or vibration-damping mounting brackets.
4. Select Floor Stands - These are optional.
  • Determine if floor stands are required. Consult your Tapeswitch application specialist.
  • If required, select the number of floor stands required.
5. Select Mirror Assemblies - These are optional.
  • Determine if mirrors are required. Consult your Tapeswitch application specialist.
  • If required, select the appropriate mirror type from the table.
Mirror Assemblies
Curtain Length
Mirror Assembly Length
Part Number
200 mm (8")
300 mm (12")
0960
300 mm (12")
400mm (16")
0961
400mm (16")
500mm (20")
0962
600 mm (24")
700 mm (28")
0963
800 mm (32")
900 mm (36")
0964
900 mm (36")
1000 mm (40")
0965
1000 mm (40")
1100 mm (44")
0966
1200 mm (48")
1300 mm (52")
0967
1400 mm (56")
1500 mm (60")
0968
6. Select Safety Controller - This is optional, but recommended.
  • Determine if a safety controller is required.
  • If required, select a safety controller: BSRSA, BSRUA-2, SRUB, SRUS, C6, or BC-1.
7. Select Power Supply - This is optional.
  • If an SRUB Safety Controller has been selected, determine if you need a power supply.
  • If required, select the GDC1 Power Supply.
8. Select Additional Accessories - These optional accessories provide useful functions for installing, maintaining and troubleshooting the light curtains.
Programming Unit - Used to program fixed and floating blanking on the sensing units.

Laser Alignment Tool - Provides a visual indication of alignment between the emitting and receiving unit. Simplifies alignment, especially when then units are far apart.

Diagnostic Software Kit - Interfaces the safety light curtain sensing units to a laptop computer. Shows real-time status of each beam and logs data.

Online Store
Trade Shows
Online Catalog
Technical Reference
Track Shipments
Home | Online Store | Switches | Mats | Sensing Edges | Sensing Bumpers | Controllers | Light Curtains | Custom Designs | Interlocks

© 2009 Tapeswitch Corporation  [  Legal  -  Privacy  -  Admin  ]

Japan Tapeswitch USA Tapeswith Germany Tapeswitch Tapeswitch UK Canada Londonmat